Biochrom Ultrospec 4300 Pro UV-Visible Spectrophotometer (190 to 1100nm)

Biochrom Ultrospec 4300 Pro UV-Visible Spectrophotometer (190 to 1100nm)

Available quantity:1

Description

This Biochrom Ultrospec 4300 pro UV-visible spectrophotometer is in good working order with an 8-place multi-cell carousel sample holder installed. This unit also includes a sipper module (P/N 80-2112-15) with the required 10mm single cell holder (P/N 80-2106-05) and user manual CDs (as seen in photos). Software is NOT included.

The Biochrom Ultrospec 4300 pro UV-visible spectrophotometer is designed for high resolution scanning for assessment of impurities in sample preparations with bandwidth of less than 1.8 nm. It provides accurate and reliable resolution, stability, wavelength accuracy and reproducibility necessary for detailed spectral scanning. 

Specifications:

Wavelength Range: 190-1100 nm, in 0.1nm steps

Scanning Speed: 6200 nm/minute maximum, 1 nm step

Monochromator: Concave grating with 1200 lines/mm

Wavelength calibration: Automatic upon switch-on

Spectral bandwidth: < 1.8nm

Wavelength accuracy: ± 0.7nm

Wavelength reproducibility: ± 0.2nm

Light sources: Tungsten halogen and deuterium arc

Detector: Single solid state silicon photodiode

Photometric range: - 3.000 to + 3.000 A, 0.01 to 99999 concentration units, 0.1 to 200 %T

Photometric linearity: ± 0.5% or ± 0.003 A to 3.000 A at 546nm, whichever is the greater

Photometric reproducibility: Within 0.5% of absorbance value to 3.000A (at 546nm)

Stray light typically: <0.025%T at 220nm using NaI, <0.025%T at 340nm using NaNO2

Stability Warm Up: ± 0.001A/h at 340 nm at 0A after

Noise: ± 0.001A near 0A and ± 0.002A near 2A at 546 nm

Sample compartment size: 5.5" W x 8.6" D x 3.4" H(14 x 22 x 8 cm)

The Sipper unit is an integrated, rapid sampling accessory that facilitates quick and easy sample handling, with no need to change cells between measurements. It comprises a peristaltic pump, pump tubing and a 10mm pathlength UV silica flowcell. It is easily fitted into the spacious sample compartment of the spectrophotometer and is controlled from the instrument keypad. The robust design of the pump means that different types of tubing can be installed for the sampling of aggressive solvents.

Volume range: 0.25 to 9.99 mL with calibration facility

Flowcell: 10 mm pathlength, 80 μl pathlength, UV grade silica

Cross contamination: Typically 0.5 % for 1 mL of aqueous solution

Pump tubing materials Pump head - Marprene; transport tubing - PTFE


** SEE LINKS TO LITERATURE FOR MORE INFORMATION

Specifications

ManufacturerBiochrom
ModelUltrospec 3100 Pro
ConditionUsed
Serial Number97853
MPN80-2112-43, 80-2112-15 and 80-2106-05
Condition DescriptionIN GOOD WORKING ORDER
Wavelength Range (nm)190 – 1100
Electrical Requirements100-240V, 50/60hZ, 150vA
Electrical Approval / CertificationCSA
Dimensions20"W x 14"D x 7.5"H
Weight (lbs)29
Country/region of manufactureUnited Kingdom